Torrance Chase Covers for Boxed Chimneys That Leak
Where Is the Water Showing?
Name the street and the sign you have spotted indoors or on the roof. A Pewter crew member calls back to plan the visit.
What This Job Covers
Factory-built fireplaces often end in a wood-framed chimney with a sheet metal lid. Cheap galvanized lids rust, sag in the middle and hold a puddle that drains through the flue hole into the framing. We measure the lid, where the flue sits and the siding below, then fit a stainless cover with a raised center, a sealed flue collar and skirts that hang past the siding. Rotten framing is noted for repair.
How a Chase Top Fails and Where the Water Goes
Many Torrance homes and townhomes built from the 1970s on have a factory-built fireplace. Its steel firebox and steel flue climb inside a wood-framed box, either built against an outside wall or rising through the roof. That box wears the same siding or stucco as the house, and its top is closed with a sheet metal lid that the flue passes through. That lid takes every storm. Builders often used thin galvanized steel, cut flat, and in salt air that steel rusts, first as orange streaks running down the stucco below the top, then as pinholes. Flat lids also sag over time, so rain pools in the middle and sits there until it finds a seam or a rust hole. The water then drops inside the enclosure, down onto the framing and insulation and the top of the metal fireplace. Inside the house, it shows up as a stain on the wall above or beside the fireplace, rust on the firebox floor, or a musty smell when the fireplace is cold.
By the time owners call us, the water has sometimes been running inside the chase for years. So the visit is more than measuring for a new lid. We look inside the enclosure, as far as the opening allows, for wet or soft framing and stained insulation, and look at the metal flue for rust. We check the seal around the flue where it passes through the lid and the cap on top. If the framing has rotted, that needs a carpenter before the new cover goes on, and we tell you so rather than closing up a wet box. When the framing is sound, the notes still say how long the water has likely been getting in and whether the fireplace's own metal shows rust, so you know whether to have the firebox looked at as well. Townhome associations in Torrance and Carson often have the same builder's cover on every unit, and one failing usually means the rest are not far behind.
What a Proper Replacement Cover Looks Like
A replacement chase cover is built to the exact top of your enclosure, in stainless steel or another metal that holds up to coastal air. The middle is peaked or creased corner to corner so it sheds water instead of holding it, and the edges fold down the outside of the enclosure and kick out at the bottom, so drops fall away from the stucco or siding. The opening for the flue is sized to the pipe and raised a little above the surface, so water on the lid cannot run down the hole. A clamped band around the flue closes the gap where pipe meets lid, and the maker's cap goes back on top. Fasteners go into the side of the enclosure rather than through the top, so there are no new holes in the surface that sheds the rain.
Chase covers are priced by the size and shape of the enclosure, the metal you choose and what we find inside, so there is no published figure. The written quote shows the cover, the flue seal, the cap if it needs replacing, and any repair to the framing or siding at the top as separate lines. Tell us through the contact page whether you can see rust streaks or a sagging top from the ground, and whether the fireplace inside has shown rust or damp. If you live in a complex where the association handles the exterior, let us know who to send the quote to. Covers on single homes are usually measured on the first visit and fitted on a second once the stainless has been made to size, and the old cover is hauled away. We can quote several units in the same building on one roof walk.
The Pewter Way of Working
Source First
The leak or fault is traced before a price is set
Photo Record
Every finding carries a dated picture and a location
Price on Paper
Our listed price, or a written scope before work
Water Retest
Repairs get a second soaking before we leave
Towns where Pewter offers chimney chase cover
Search for your town below. The South Bay towns come first, and their pages describe the local houses and the leaks we find in them.
Nothing on our list matches. Type the next town over, or send your street through the contact page.
More Chimney and Fireplace Work
Chimney Sweep
Flue brushed top to bottom and the soot vacuumed, with a note on any damp patch, stained tile or rusted damper we pass.
Open →Chimney Inspection
Level 1 or Level 2, with each finding traced to the part of the chimney it comes from.
Open →Chimney Repair
Crowns, joints, flashing and flue tile put right once we know which one is letting water in.
Open →Fireplace Inspection
Inside the room we look over the hearth, smoke chamber, damper and firebox, with any sign of rain coming down the flue written up.
Open →Fireplace Repair
Firebrick, back wall, smoke chamber and damper repaired with heat-rated materials once the water feeding the damage is stopped.
Open →Chimney Level 2 Inspection
Video scan of every flue plus attic and framing checks, for a sale, a quake, a chimney fire or a stubborn leak.
Open →Chimney Cap Installation
A stainless or copper cap fastened over the flue to keep rain, leaves and animals out, quoted after we measure.
Open →Chimney Flashing Repair
Roofline drips followed to their entry point and the metal relaid in the right overlap, with a cricket added behind a wide stack.
Open →Chimney Masonry Repair
Spalled brick, washed-out joints and cracked crowns repaired with a mortar soft enough to let the brick dry out.
Open →Chimney Rebuilds
Stacks too far gone to patch are taken down to solid courses and laid again with steel, flashing, a new crown and a cap.
Open →Fireplace Cleaning
Ash, soot and glass cleaned from the room side, with rust, damp brick or a musty smell noted for a closer look.
Open →Gas Fireplace Cleaning
Glass, ceramic logs, pilot and burner cleaned, and the vent outlet outside checked for rust, nests and rain getting in.
Open →Gas Fireplace Repair
Pilot, sensor, valve and igniter faults found with a meter, and rust damage from a leaking vent repaired at the source.
Open →Fireplace Remodel
New surround, mantel or hearth built within the code distances, with old water damage behind the facing fixed first.
Open →Fireplace Inserts
A gas or wood insert fitted into an existing opening, with a full-height liner and a cap that keeps rain off it.
Open →Pellet Stove Repair
Error codes read, motors and igniter metered, and the outside vent inspected for rain that swells pellets in the feed.
Open →Wood Stove Repair
Door seals, baffle, firebrick and stovepipe renewed, with rust from a leaking roof pipe traced to the top.
Open →Gas Logs
Vented log sets placed on a dry, clean flue, with the damper held open and the gas line run to code.
Open →Chimney Seismic Retrofit
Brick stacks tied back to the house frame or rebuilt lighter above the roof, starting with whether the brick can hold steel.
Open →Chimney Crown Repair
Cracked crowns sealed or recast with an overhang, so rain lands on the roof instead of soaking into the brick.
Open →Dryer Vent Cleaning
Lint cleared from the duct and the outside hood checked so its flap closes against rain and pests.
Open →Chimney Liner Installation
Cracked or missing flue tile replaced by a stainless liner sized to the appliance, capped so rain cannot run down it.
Open →Chimney Leak Repair
Ceiling stains and damp walls traced back to the crown, cap, flashing or joint, then fixed at that point.
Open →Chimney Waterproofing
A repellent that lets brick breathe, applied after cracks and joints are fixed, so the stack stops soaking up rain.
Open →Chimney Damper Repair
Rusted, warped or seized dampers freed, rebuilt or swapped for a top-mounted damper that also shuts out rain.
Open →